Add to Cart
Dc to ac off grid pure sine wave inverter 1000w 1500w 2000w inverter 24vdc to 220vac
Model : GI-15224
Descriptions:
High Transfer efficiency:≥90%
Continuous stable pure sine wave output
AC Charging current 0-35A adjustable
7 battery types optional
AC mains input frequency 50Hz/60Hz automatic recognition
BATTERY TYPE (optional)
Position | Float | Position | Float(V) |
U0=Gel U.S.A | 13.7V | U4=Gel European | 13.8V |
U1=A.G.M.1 | 13.4V | U5=Open lead acid | 13.8V |
U2=A.G.M.2 | 13.7V | U6=Calcium(open) | 13.6V |
U3=Sealed lead Acid | 13.6V |
Top One: No matter how low or how high the AC input voltage is, with voltage stabilizer our Power inverter provides standard 110V or 110V stable output, which keeps the loading works stably. Wide stabilizing range of AC input optional.
----------------------------------
Others: Only a few Power inverter in the market has stabilizer technology, even they have, they can only provide short time stabilization but not continuously. So the loading can work in short time stably only but not long time. Or their stabilizing range is not wide as ours.
GI Series Low Frequency Pure Sine Wave Inverter (220V) | ||||||||
Model | GI-102 | GI-152 | GI-202 | GI-302 | GI-402 | GI-502 | GI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥92% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤4ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
3 Stages charging | Boost charging, direct charging, float charging | |||||||
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
Working mode (Optional) | 01 | AC mains priority | ||||||
Always use AC mains as priority input to provide AC output and automatically charge the battery, only | ||||||||
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | ||||||||
02 | Energy saving | |||||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | ||||||||
03 | DC battery priority | |||||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts | ||||||||
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC | ||||||||
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) | ||||||||
Comnunication | RS-232/USB/SNMP(additional option) | |||||||
Environment | Temperature | -20~75℃ | ||||||
Humidity | <95% | |||||||
Appearance | Product size (mm) | 430*310*270mm | 600*270*200mm | |||||
Packing size (mm) | 540*350*300mm | 720*310*270mm | ||||||
Net Weight (kg) | 15kg | 17kg | 24.5kg | 29kg | 44kg | 48.1kg | 49.5kg | |
Gross Weight (kg) | 16.5kg | 19kg | 27kg | 31kg | 46kg | 50.1kg | 52.2kg | |
*Product specifications are subject to change without further notice |
Applications:
All kinds of home appliance ,office equipment ,solar power system, and other equipment which use single phase power.
Competitive Advantage:
1. Suitable for all electrical equipment
2. Intelligent temperature control:Heat value of our inverter is every low
3. Pure copper transformer: high quality materials for the whole series
4. Super load capacity: three times peak power of rate power,Three times peak power with one time soft start
5. Two layers PCB board: real isolated input and output, they will not influence each other during operating. Such design is in order to improve the stability of the inverter, and it is easy to detect faults and maintain.
6. Transfer efficiency: ≥93%
7. Warranty:1 year